Cart

  • Cart Empty!
Magnum VS 50 with SNMP - GMT Fuse Distribution

Magnum VS 50 with SNMP - GMT Fuse Distribution

£1,612.84 
£1,935.41 
Part Number: DCM00K03SGMT
Language: NS
Real time Stock Check

Product Details

Introduction

Magnum VS 50 w/SNMP -- GMT FUSE DISTRIBUTION Reliable and flexible DC power solutions for customer premise broadband, low power wireless and other telecommunication applications. Includes : Rack Mounting Brackets , User Manual - Battery voltage temperature compensation Automatic battery float voltage temperature compensation extends battery life and performance - Cable Entry Configurable for either top or bottom cable entry. - Dry Contact inputs User assignable inputs allow other equipment alarms to be monitored through the power system controller - Integral low voltage disconnect Automatic LVD function extends battery life by preventing damage caused by deep discharge. Manageability - LED Indicators Provide easy-to-read status of the unit and utility power conditions. - Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Availability - Internal Protection Integral over-current protection devices protect the system against overload faults. - Battery voltage temperature compensation Automatic battery float voltage temperature compensation extends battery life and performance - Extendable Run Time Additional batteries can be added to provide power to the load for an extended period of time in the event of utility supply failure. Serviceability - Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced - User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) - Front Access Installation and maintenance of all components can be carried out without access to the rear or sides of the cabinet. - Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.

Specifications


Product typePower supply
Product colourBlack
LED indicatorsAlarm, Network, Status
Power protection featuresOver current
CertificationCE, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, UL 1950
Total power500 W
AC input voltage88 - 264 V
AC input frequency47-67 Hz
Maximum current5.5 A
Operating temperature (T-T)-40 - 55 °C
Storage temperature (T-T)-40 - 85 °C
Operating relative humidity (H-H)0 - 85%
Storage relative humidity (H-H)0 - 95%
Operating altitude0 - 9000 m
Operating temperature (T-T)-40 - 131 °F
Width438 mm
Depth330 mm
Height133 mm
Weight9.5 kg
.